When the IP address of Kaspersky IoT Secure Gateway 1000 in the internal network is changed, the web interface connection session will be closed and you will be redirected to the page for resuming a connection session with the Kaspersky IoT Secure Gateway 1000 web interface.
When the network mask of Kaspersky IoT Secure Gateway 1000 in the internal network is changed, you must reconfigure the internal network settings.
When the Use DHCP server feature is enabled or disabled, you must restart Kaspersky IoT Secure Gateway 1000.
To configure the LAN settings:
In the menu in the left part of the web interface page, select Settings → Network.
On the LAN tab, specify values for the following parameters:
IP address. The default value of this parameter is 192.168.1.1.
Subnet mask. The default value of this parameter is 255.255.255.0.
The MAC address field displays the MAC address of the system in the internal network.
If you want to configure network settings automatically via DHCP for the devices in the internal network, set the Use DHCP server toggle button to Enabled and specify values for the following settings:
Start of IP address range.
End of IP address range.
Primary DNS server address.
Secondary DNS server address.
By default, the Use DHCP server toggle button is switched on.
If you want to configure network settings manually for the devices in the internal network, set the Use DHCP server toggle button to Disabled.
Click Save in the lower part of the page to save the changes.
Restart Kaspersky IoT Secure Gateway 1000 to apply the changes to the network settings.