Connect to the Kaspersky Industrial CyberSecurity for Networks Server through the web interface using the Administrator account.
Select Settings → Event types.
In the table of event types, select the event type that you want to edit. If the event type provides for registration of events with multiple severity levels, select the table row of the event type with the relevant severity level.
The details area appears in the right part of the web interface window.
Click the Edit button.
Configure the editable settings, such as the event regeneration period and settings for saving traffic.