Enabling and disabling test mode

To enable test data synchronization mode:

  1. In the main window of the web interface, select the Users section.
  2. Click Import users.

    The Import and synchronization window opens.

  3. Select the Local Active Directory service tab.
  4. Enable test synchronization mode via the Test mode slider.
  5. Click the Save button.

Data synchronization test mode will now be enabled. All records of changes made by application users will be displayed in the synchronization request history, but won't be recorded in the application database.

Before disabling test mode, make sure that all application users are correctly synchronized with Active Directory accounts and placed in the proper groups after automatic assignment rules have been applied. To do this, view the synchronization history.

You can't disable test synchronization mode for Entra ID and the local AD service at the same time. If you want to start basic synchronization mode with the local AD service, you need to enable test synchronization mode for Entra ID.

To switch from the test mode of Active Directory synchronization to the main mode:

  1. In the main window of the web interface, select the Users section.
  2. Click Import users.

    The Import and synchronization window opens.

  3. Select the Local Active Directory service tab.
  4. Disable test synchronization mode via the Test mode slider.
  5. Click the Save button.

Active Directory synchronization will now launch in the main mode. All data obtained from synchronization will be recorded in the application database.