File with descriptions of connections and protocols: connections.csv

The protocol description file contains descriptions of protocols for each connection.

The file should begin with header strings containing the data needed for file processing. An example of header strings of the connections.csv file is provided below.

Example:

'Connections

'Format Version V1.0.0.0;KICS Importer Version V1.0.0.0

'Field separator: ; Decimal separator: . Text quotes: " Var name separator: .

'Connection;Protocol;Address

The first three header strings are identical to the header strings in the devices.csv file.

The string Connection;Protocol;Address contains the names of columns with data:

The header strings are followed by the file body containing the values of parameters (connection ID, application-level protocol code, full network address of the device). An example of the connections.csv file is provided below.

Example:

'Connections

'Format Version V1.0.0.0;KICS Importer Version V1.0.0.0

'Field separator: ; Decimal separator: . Text quotes: " Var name separator: .

'Connection;Protocol;Address

"ms_plc";3;"IP-Address=192.168.0.77;Port=1025"

"mc_SysQ";7;"IP-Address=192.168.0.77;Port=2404;Asdu=555"

The format of the device network address in the file connections.csv depends on the type of protocol used.

Example:

The following address formats can be used for protocols supported by Kaspersky Industrial CyberSecurity for Networks:

  • MODBUS TCP:

    "IP-Address=192.168.0.7;Port=502"

  • SIEMENS S7COMM over TCP:

    "IP-Address=192.168.0.7;Port=502;Rack=0;Slot=2"

  • SIEMENS S7COMM over INDUSTRIAL ETHERNET:

    "MAC=00:01:02:03:04:05;Rack=0;Slot=2"

  • MITSUBISHI MELSEC SYSTEM Q:

    "IP-Address=192.168.0.7;Port=502;Network=0;Station=0;PC=255"

  • ALLEN-BRADLEY ETHERNET/IP:

    "IP-Address=192.168.0.7;Port=44818"

  • IEC 61850 MMS:

    "IP-Address=192.168.0.7;Port=502;Domains=IED_0009CTRL,IED_0009PROT;Vendor=SIEMENS;Model=Siprotec-6MD66x"

  • IEC 61850 GOOSE:

    "Domains=IED_0009CTRL,IED_0009PROT;Vendor=SIEMENS;Model=Siprotec-6MD66x"

  • IEC 60870-5-104:

    "IP-Address=192.168.0.7;Port=104;Asdu=2"

  • GENERAL ELECTRIC SRTP:

    "IP-Address=192.168.0.50;Port=18245"

  • IEC 61850 SAMPLED VALUES:

    "MAC=00:01:02:03:04:05;Domains=IED_TRANSFORMER1;Vendor=TMW;Model=IED"

  • SIEMENS S7COMMPLUS over TCP:

    "IP-Address=192.168.0.22;Port=102"

  • EMERSON DELTAV:

    "IP-Address=192.168.0.38;Port=18507"

  • OMRON FINS over UDP:

    "IP-Address=192.168.0.1;Port=9600"

  • MMS for ABB AC 800M:

    "IP-Address=192.168.0.60;Port=102"

  • YOKOGAWA VNET/IP:

    "IP-Address=192.168.0.4;Port=5313"

  • CODESYS V3 GATEWAY over TCP:

    "IP-Address=192.168.0.4;Port=11740"

  • DNP3:

    "IP-Address=192.168.1.10;Port=20000"

  • OMRON FINS over TCP:

    "IP-Address=192.168.0.1;Port=9600"

  • OPC UA BINARY:

    "IP-Address=192.168.0.213;Port=49320"

  • DMS for ABB AC 700F:

    "IP-Address=192.168.0.7;Port=9991"

  • OMRON FINS over ETHERNET/IP:

    "IP-Address=192.168.0.1;Port=44818"

  • OPC DA:

    "IP-Address=192.168.0.7;Port=135"

  • CODESYS V3 GATEWAY over UDP:

    "IP-Address=192.168.0.7;Port=1740"

  • BECKHOFF ADS/AMS:

    "IP-Address=192.168.0.7;Port=48898"

  • IEC 60870-5-101:

    "IP-Address=192.168.0.7;Port=950"

  • EMERSON CONTROLWAVE DATA EXCHANGE:

    "IP-Address=192.168.0.7;Port=1234"

  • HONEYWELL CONTROLEDGE 900 INTERACTION:

    "IP-Address=192.168.1.99;Port=41103"

Page top