Types of events in Kaspersky Security Center for Kaspersky Industrial CyberSecurity for Networks events

A fixed set of event types are used for receiving events of Kaspersky Industrial CyberSecurity for Networks in Kaspersky Security Center. The types of events in Kaspersky Security Center correspond to the specific types of events in Kaspersky Industrial CyberSecurity for Networks and can be registered as Kaspersky Security Center incidents depending on the severities of the events (see the figure below).

Types of events in Kaspersky Security Center for receiving events of Kaspersky Industrial CyberSecurity for Networks

Displayed name of the event type

Registration as a Kaspersky Security Center incident

Corresponding event type code in Kaspersky Industrial CyberSecurity for Networks

Test event (DPI)

no

4000000001

Test event (NIC)

no

4000000002

Test event (IDS)

no

4000000003

Test event (AM)

no

4000000004

Unauthorized network interaction detected

no

4000002601

System command detected

Only events with the Critical severity level

4000002602

No traffic at monitoring point

no

4000002700

TCP protocol anomaly detected: content substitution in overlapping TCP segments

yes

4000002701

Process Control rule violation

Only events with the Critical severity level

4000002900

Intrusion Detection rule from the system set of rules was triggered

no

4000003000

Intrusion Detection rule from the custom set of rules was triggered

no

4000003001

Symptoms of ARP spoofing detected in ARP replies

yes

4000004001

Symptoms of ARP spoofing detected in ARP requests

yes

4000004002

New device detected in network

yes

4000005003

New device settings detected

no

4000005004

IP address conflict detected

yes

4000005005

Activity detected from asset with Archived status

no

4000005006

New IP address of device detected

yes

4000005007

New MAC address of device detected

yes

4000005010

IP address added to device

no

4000005009

MAC address added to device

no

4000005008

IP protocol anomaly detected: data conflict when assembling IP packet

yes

4000005100

IP protocol anomaly detected: fragmented IP packet size exceeded

yes

4000005101

IP protocol anomaly detected: the size of the initial fragment of the IP packet is less than expected

yes

4000005102

IP protocol anomaly detected: mis-associated fragments

yes

4000005103

PLC Project Control: detected read of unknown block from PLC

no

4000005200

PLC Project Control: detected read of known block from PLC

no

4000005201

PLC Project Control: detected write of new block to PLC

no

4000005202

PLC Project Control: detected write of known block to PLC

no

4000005203

PLC Project Control: detected read of unknown project from PLC

no

4000005204

PLC Project Control: detected read of known project from PLC

no

4000005205

PLC Project Control: detected write of new project to PLC

no

4000005206

PLC Project Control: detected write of known project to PLC

no

4000005207

Correlation rule event registered

Only events with the Critical severity level

8000000000, 8000000001, 8000000002, 8000000003

Maximum number of reported events has been reached

yes

User event based on Deep Packet Inspection technology

Only events with the Critical severity level

User event based on External technology

yes

Page top