This section provides a description of system event types associated with Asset Management technology (see the table below).
System event types based on Asset Management technology (AM)
Code |
Title of event type |
Severity |
Registration conditions |
---|---|---|---|
4000005003 |
Detected new device with the address $owner_ip_or_mac |
Critical |
Asset Management monitoring mode resulted in the automatic addition of a new device based on a detected IP address or MAC address that has not been specified for other devices in the table. The following variables are used in the title and description of an event type:
|
4000005004 |
Received new information about device with the address $owner_ip_or_mac |
Informational |
Asset Management monitoring mode resulted in the automatic update of device information based on data obtained from traffic. The following variables are used in the title and description of an event type:
|
4000005005 |
IP address $owner_ip conflict detected |
Critical |
In Asset Management monitoring mode, the application detected the use of an IP address by a different device than the device for which this IP address was specified. The following variables are used in the title and description of an event type:
|
4000005006 |
Detected traffic from address $owner_ip_or_mac, which is assigned to a device with the Archived status |
Critical |
In Asset Management monitoring mode or based on data received from an EPP application, activity was detected from a device that was assigned the Archived status. The following variables are used in the title and description of an event type:
|
4000005007 |
A new IP address $new_ip_addr was detected for the device with MAC address $owner_mac |
Critical |
In Asset Management monitoring mode, a new IP address used by a device was detected. The following variables are used in the title and description of an event type:
|
4000005008 |
MAC address $owner_mac was added to the device with IP address $owner_ip |
Informational |
Asset Management monitoring mode resulted in the automatic addition of a MAC address for a network interface for which only an IP address was specified (the device had the Unauthorized or Archived status). The following variables are used in the title and description of an event type:
|
4000005009 |
IP address $owner_ip was added to the device with MAC address $owner_mac |
Informational |
Asset Management monitoring mode resulted in the automatic addition of an IP address for a network interface for which only a MAC address was specified (the device had the Unauthorized or Archived status). The following variables are used in the title and description of an event type:
|
4000005010 |
Detected new MAC address $new_mac_addr for device with the IP address $owner_ip |
Critical |
Asset Management monitoring mode resulted in the detection of a new MAC address used by a device (autoupdate of address information is disabled for the device). The following variables are used in the title and description of an event type:
|
4000005011 |
Change of MAC address $owner_mac to $challenger_mac detected in device information received from EPP application |
Critical |
The MAC address of a device was updated according to data received from an EPP application. The following variables are used in the title and description of an event type:
|
4000005012 |
New address information of device $asset_name detected in data received from EPP application |
Critical |
New address information of a device was detected in data received from an EPP application. This type of event is registered if a change in device address information was not processed by the application as an event with code 4000005009 or 4000005010. The following variables are used in the title and description of an event type:
|
4000005013 |
Conflict detected in addresses of devices $conflicted_epp_assets after data received from EPP application |
Critical |
Based on data received from an EPP application, a conflict was detected in the addresses of multiple devices in Kaspersky Industrial CyberSecurity for Networks. According to data from the EPP application, the addresses belong to the same device. The following variables are used in the title and description of an event type:
|
4000005014 |
Subnet $subnet_mask added based on data from EPP application |
Critical |
After data was received from an EPP application, a new subnet was automatically added to the list of known subnets. The following variables are used in the title and description of an event type:
|
4000005200 |
PLC Project Control: detected read of unknown block from PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected read of an unknown block of a project from a PLC (if there is no saved information about this block). The following variables are used in the title and description of an event type:
|
4000005201 |
PLC Project Control: detected read of known block from PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected read of a known block of a project from a PLC (if there is saved information about this block but the received information does not match the latest saved information about this block). The following variables are used in the title and description of an event type:
|
4000005202 |
PLC Project Control: detected write of new block to PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected write of an unknown block of a project from a PLC (if there is no saved information about this block). The following variables are used in the title and description of an event type:
|
4000005203 |
PLC Project Control: detected write of known block to PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected write of a known block of a project from a PLC (if there is saved information about this block but the received information does not match the latest saved information about this block). The following variables are used in the title and description of an event type:
|
4000005204 |
PLC Project Control: detected read of unknown project from PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected read of an unknown project from a PLC (if there is no saved information about this project). The following variables are used in the title and description of an event type:
|
4000005205 |
PLC Project Control: detected read of known project from PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected read of a known project from a PLC (if there is saved information about this project but the received information does not match the latest saved information about this project). The following variables are used in the title and description of an event type:
|
4000005206 |
PLC Project Control: detected write of new project to PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected write of a new project to a PLC (if there is no saved information about this project). The following variables are used in the title and description of an event type:
|
4000005207 |
PLC Project Control: detected write of known project to PLC $asset_name |
Critical |
PLC Project Control read/write monitoring resulted in a detected write of a known project to a PLC (if there is saved information about this project but the received information does not match the latest saved information about this project). The following variables are used in the title and description of an event type:
|
4000005300 |
Detected vulnerability $cve_id |
Critical |
Device vulnerability detected for the first time or a vulnerability had been previously switched to the Remediated state (for example, if modified device information once again matches a device description in a vulnerability with the same CVE ID). The following variables are used in the title and description of an event type:
|
4000005303 |
Modified information about vulnerability $cve_id |
Critical |
Changes detected in a vulnerability that did not impact its current state (for example, if additional recommendations on system protection were added when the database of known vulnerabilities was updated). The following variables are used in the title and description of an event type:
|
4000000004 |
Test event (AM) |
Informational |
A test network packet was detected (with the device activity detection method enabled). |