Configuring port mirroring for Siemens SCALANCE switches

For more information about configuring port mirroring for Siemens SCALANCE switches, refer to Siemens equipment documentation.

To configure port mirroring for Siemens SCALANCE switches:

  1. Connect to the switch web interface and select Layer 2Mirroring.
  2. To create a mirroring session:
    1. Select the General tab.
    2. Enable Mirroring.
    3. To create a record in the table, click the Create button.

      The session ID is assigned automatically.

    4. In the Session Type drop-down list, select the Port Based value.
    5. Click the Set Values button.
    6. In the Destination Port column, select the destination port.

      For example, P0.8.

    7. Click the Set Values button.
  3. Select the Port tab.
  4. In the Port tab follow these steps:
    1. In the Session ID drop-down list, select the ID of the session you created earlier in the General tab.
    2. To monitor all data traffic of a port, select all the ports in the table in the Ingress and Egress columns.
    3. Click the Set Values button.