When creating a Manual-TE path, you must manually specify the links that the path passes through on the way from the segment source CPE device to the segment destination CPE device. Two types of Manual-TE paths are supported:
You can use Manual-TE constraints to add Manual-TE paths to transport services.
Examples of possible Manual-TE paths: In the examples, an OpenFlow port number is specified after the CPE device number, separated by a colon. Fully defined Manual-TE path: CPE 1:3 → CPE 2:1, CPE 2:2 → CPE 4:1, CPE 4:5 → CPE N:2. Hybrid Manual-TE path: CPE 1 → CPE 5, CPE 5:3 → CPE 4:3, CPE 4 → CPE N. In this case, the path from CPE 1 to CPE N is built as an Auto-SPF path CPE 1 → CPE 5, a Manual-TE path CPE 5:3 → CPE 4:3, and an Auto-SPF path CPE 4 → CPE N. |
To create a Manual-TE path:
This opens the resource management page. By default, the Network resources tab is selected, which displays the table of controllers.
This opens the controller configuration menu. By default, you are taken to the Controller nodes section, which displays a table of controller nodes.
A table of segments is displayed.
The settings and the path table are displayed.
The Manual-TE path settings and the hop table are displayed.
4
.If you are adding the first hop to the Manual-TE path, you can select only the CPE device of the segment source as the source CPE device of the hop. If you have added at least one hop to the Manual-TE path, you can only select the destination CPE device of the previous hop as the source CPE device of the current hop.
If in the Port drop-down list you selected Automatically as the hop source CPE device, you can select any CPE device that is not being used in other hops as the hop destination. In this case, in the Port drop-down list, Automatically is selected for the hop destination CPE device, and the OpenFlow port is detected automatically. Thus, the hop uses an Auto-SPF path.
If in the Port drop-down list, you selected an OpenFlow port for the hop source CPE device, for the hop destination CPE device, you can only use a CPE device that has a link built from that OpenFlow port. In this case, in the Port drop-down list, the OpenFlow port to which the link is built is automatically selected as the hop destination CPE device. Thus, the hop uses the link specified between the two CPE devices.
The hop is created and displayed in the table. You can add multiple hops or delete a hop. To delete a hop click Delete next to it.
A check is performed to make sure the destination CPE device of the last hop matches the destination CPE device of the segment in which you are creating the Manual-TE path. If the check is successful, the Manual-TE path is created and displayed in the table, and the column Cost displays the cost of the Manual-TE path, which is the sum total of the cost of all hops that you added to this Manual-TE path.