Deleting a UNI

You can delete a UNI in a UNI template or on a CPE device. A UNI deleted in the UNI template is automatically deleted on all CPE devices that use this UNI template.

Deleted UNIs cannot be restored.

Deleting a UNI in a UNI template

To delete a UNI in a UNI template:

  1. In the menu, go to the SD-WAN → UNI templates subsection.

    A table of UNI templates is displayed.

  2. Click the UNI template in which you want to delete a UNI.

    The settings area is displayed in the lower part of the page. You can expand the settings area to fill the entire page by clicking the expand icon expand_panel_up_icon_2. By default, the Information tab is selected, which displays the UNI template name and the tenant to which the UNI template is assigned.

  3. Select the UNIs tab.

    A table of UNIs is displayed.

  4. Click Delete next to the UNI that you want to delete.

    The UNI is deleted and is no longer displayed in the table.

  5. In the upper part of the settings area, click Save to save UNI template settings.

Deleting an UNI on a CPE device

You cannot delete a UNI if it is being used by at least one network service. You need to look up the usage of the UNI and make sure that it is not in use.

To delete a UNI on a CPE device:

  1. In the menu, go to the SD-WAN → CPE section.

    A table of CPE devices is displayed.

  2. Click the CPE device on which you want to delete a UNI.

    The settings area is displayed in the lower part of the page. You can expand the settings area to fill the entire page by clicking the expand icon expand_panel_up_icon_2. By default, the Configuration tab is selected, which displays general information about the CPE device. This tab also displays the table of Out-of-band management tasks being performed by the orchestrator.

  3. Select the UNIs tab.

    A list of UNIs is displayed.

  4. Click Management → Delete next to the UNI that you want to delete.
  5. In the confirmation window, click Delete.

    The UNI is deleted and is no longer displayed in the table.

  6. In the upper part of the settings area, click Save to save CPE device settings.
Page top