An error occurs when enabling a monitoring point

Problem

After the monitoring point switches to Enabled, a status of Error is displayed. As a result, the node associated with this monitoring point will display a status of Operation disrupted. The list of notifications about application operating issues also shows a message regarding disrupted operation due to detected issues at the monitoring point.

Solution

An Error status of the monitoring point may be associated with an unsupported operational state of a network interface. For successful completion of a scan when a monitoring point is enabled, the network interface must have the UP operational state. If the network interface is in a different operational state. such as UNKNOWN, the application assigns a status of Error to the monitoring point because of possible problems when receiving or processing network packets.

You can use the ip link command to check the current operational state of a network interface on a node computer. Information about the current operational state is displayed in the string containing the name of the interface in the following format: state <state>. The most likely operational states on a problematic network interface are as follows:

When the network interface switches to the UP operational state, check the status of the monitoring point added to this network interface. If the monitoring point is still displayed with a status of Error, disable and then re-enable this monitoring point.

Page top