Operational correlation rules are used for working with active lists.
The correlation rule window contains the following tabs:
General tab
If correlation rules employing complex logic for pattern detection are not triggered, this may be due to the specific method used to count rule triggers in KUMA. In this case, try to increase the value of Rate limit to 1000000
, for example.
Selectors tab
A rule of the operational kind can have only one selector for which the Settings and Local variables tabs are available.
The Settings tab contains settings with the Filter settings block:
On the Local variables tab, use the Add variable button to declare variables that will be used within the limits of this correlation rule.
Actions tab
A rule of the operational kind can have only one trigger: On every event. It is activated every time the selector triggers.
Available parameters of the trigger:
Available settings:
The active list entry key depends on the available fields and does not depend on the order in which they are displayed in the KUMA web interface.
The field must not contain special characters or numbers only.