Viewing events when connected to Kaspersky IoT Secure Gateway 1000 via the console port

June 7, 2023

ID 224429

Kaspersky IoT Secure Gateway 1000 lets you view Kaspersky IoT Secure Gateway 1000 event logs in real time. To do this, you need to connect Advantech UTX-3117FS-S6A1N to a local computer via console port.

A console port is a control port providing out-of-band access to the Advantech UTX-3117FS-S6A1N device.

To view Kaspersky IoT Secure Gateway 1000 event logs in real time via a console port connection:

  1. Please connect a null-modem crossover cable (DB-9f/DB-9f) to the Advantech UTX-3117FS-S6A1N rear panel at one end and to a desktop or laptop computer at the other.

    If your computer does not have a null-modem crossover cable connector, you can use a USB-COM adapter.

  2. Turn on the Advantech UTX-3117FS-S6A1N.
  3. Using a terminal emulator on a local computer, connect to Advantech UTX-3117FS-S6A1N.

    Before connecting, please specify the following connection settings in your terminal emulator:

    • The data transfer rate should be 115,200 baud, or a different value if it is specifically set for the Recovery mode parameter
    • The number of data bits, availability and type of the parity bit, and the number of stop bits should be 8n1
    • Hardware flow control

Kaspersky IoT Secure Gateway 1000 events will be displayed in real time in the interface of the terminal emulation program running on the desktop or laptop.