Hardware and software requirements

Kaspersky SD-WAN has the following hardware and software requirements:

Hardware requirements depend on the number of CPE devices being managed (see the table below). If you need to connect more than 250 CPE devices, you need to deploy additional controllers. If you need to calculate hardware requirements for a specific deployment scheme more precisely, we recommend contacting Kaspersky Technical Support.

Solution component

RAM, GB

Virtual CPU

Disk, GB

IOPS

50 CPE devices

Redis replica server

1

2

100

1000

Redis Sentinel system

1

2

MongoDB database

2

2

Orchestrator

4

4

Virtual Network Function Manager (VNFM)

1

2

Proxy Virtual Network Function Manager (VNFM proxy)

1

2

Frontend part of the solution

1

2

Database of the Zabbix monitoring system

1

2

500

1000

Zabbix server

1

2

Frontend part of the Zabbix monitoring system

1

2

Zabbix proxy server

1

2

Syslog server

1

1

No value

No value

Data storage system

8

8

20

1000

Controller

8

8

64

1000

100 CPE devices

Redis replica server

1

2

100

1000

Redis Sentinel system

1

2

MongoDB database

4

4

Orchestrator

4

4

Virtual Network Function Manager (VNFM)

1

2

Proxy Virtual Network Function Manager (VNFM proxy)

1

2

Frontend part of the solution

2

2

Database of the Zabbix monitoring system

1

4

1000

1000

Zabbix server

1

2

Frontend part of the Zabbix monitoring system

1

2

Zabbix proxy server

1

2

Syslog server

1

2

No value

No value

Data storage system

8

8

20

1000

Controller

8

8

64

1000

250 CPE devices

Redis replica server

2

2

100

1000

Redis Sentinel system

2

2

MongoDB database

4

4

Orchestrator

4

6

Virtual Network Function Manager (VNFM)

2

2

Proxy Virtual Network Function Manager (VNFM proxy)

2

2

Frontend part of the solution

2

2

Database of the Zabbix monitoring system

2

4

2500

1000

Zabbix server

2

4

Frontend part of the Zabbix monitoring system

2

2

Zabbix proxy server

2

2

Syslog server

2

2

No value

No value

Data storage system

10

8

20

1000

Controller

16

8

64

1000

500 CPE devices

Redis replica server

2

2

100

1000

Redis Sentinel system

2

2

MongoDB database

4

6

Orchestrator

6

6

Virtual Network Function Manager (VNFM)

2

2

Proxy Virtual Network Function Manager (VNFM proxy)

2

2

Frontend part of the solution

2

2

Database of the Zabbix monitoring system

2

4

5000

1000

Zabbix server

2

4

Frontend part of the Zabbix monitoring system

2

4

Zabbix proxy server

2

4

Syslog server

2

2

No value

No value

Data storage system

10

8

20

1000

Controller

32

8

128

1000

1000 CPE devices

Redis replica server

2

4

100

1000

Redis Sentinel system

2

2

MongoDB database

6

6

Orchestrator

8

6

Virtual Network Function Manager (VNFM)

2

2

Proxy Virtual Network Function Manager (VNFM proxy)

2

2

Frontend part of the solution

2

2

Database of the Zabbix monitoring system

2

6

1000

1000

Zabbix server

2

6

Frontend part of the Zabbix monitoring system

2

4

Zabbix proxy server

2

4

Syslog server

2

6

No value

No value

Data storage system

12

10

20

1000

Controller

64

8

256

1000

2000 CPE devices

Redis replica server

4

4

200

2000

Redis Sentinel system

4

2

MongoDB database

8

6

Orchestrator

10

6

Virtual Network Function Manager (VNFM)

4

2

Proxy Virtual Network Function Manager (VNFM proxy)

4

2

Frontend part of the solution

4

4

Database of the Zabbix monitoring system

4

6

2000

2000

Zabbix server

4

6

Frontend part of the Zabbix monitoring system

4

6

Zabbix proxy server

4

6

Syslog server

4

6

No value

No value

Data storage system

16

12

20

1000

Controller

128

8

512

1000

5000 CPE devices

Redis replica server

6

4

500

5000

Redis Sentinel system

6

2

MongoDB database

10

6

Orchestrator

12

6

Virtual Network Function Manager (VNFM)

6

4

Proxy Virtual Network Function Manager (VNFM proxy)

6

2

Frontend part of the solution

8

4

Database of the Zabbix monitoring system

6

8

5000

5000

Zabbix server

6

8

Frontend part of the Zabbix monitoring system

6

6

Zabbix proxy server

6

6

Syslog server

6

8

No value

No value

Data storage system

32

16

50

1000

Controller

320

8

1280

1000

10,000 CPE devices

Redis replica server

8

4

1000

10,000

Redis Sentinel system

8

2

MongoDB database

12

8

Orchestrator

16

8

Virtual Network Function Manager (VNFM)

8

4

Proxy Virtual Network Function Manager (VNFM proxy)

8

2

Frontend part of the solution

8

4

Database of the Zabbix monitoring system

32

8

10,000

10,000

Zabbix server

16

8

Frontend part of the Zabbix monitoring system

8

8

Zabbix proxy server

8

8

Syslog server

8

8

No value

No value

Data storage system

64

32

100

1000

Controller

640

8

2560

1000

Third-party solution requirements

The following third-party solutions are necessary to deploy the solution:

Operating system requirements

The following 64-bit operating systems are supported:

Requirements for deployment environments of solution components

The following deployment environments are supported for solution components:

Requirements for links between nodes of solution components

When deploying Kaspersky SD-WAN, you can deploy multiple nodes of solution components. The following requirements apply to links between nodes of solution components:

Browser requirements

The following browsers are supported for managing the orchestrator web interface:

Requirements for the data storage system

We recommend using your own data storage system for fault tolerance. The following requirements apply to the data storage system:

Administrator device requirements

The administrator device for deploying the solution must satisfy the following requirements:

CPE device requirements

The following CPE device models are supported:

CPE devices of the KESR model are based on x86 (Intel 80x86) and MIPS (Microprocessor without Interlocked Pipeline Stages) processor architectures.

Kaspersky experts carried out tests to confirm the functionality of CPE devices when providing the L3 VPN service (see the table below). DPI (Deep Packet Inspection) was not used on the tested devices, and traffic encryption was disabled.

Model

Packet size (bytes)

Bandwidth (Mbps)

KESR-M1

IMIX (417)

30

Large (1300)

115

KESR-M2

IMIX (417)

165

Large (1300)

241

KESR-M3

IMIX (417)

805

Large (1300)

1150

KESR-M4

IMIX (417)

1430

Large (1300)

2870

For detailed information about the characteristics of CPE devices, please refer to the official page of the solution.

You can deploy uCPE devices on servers with x86 (Intel 80x86) or ARM64 processor architectures.

You can use the vKESR-M1 model as a vCPE device. The following virtualization environments are supported for vCPE devices:

vCPE devices of the vKESR-M1 model have the following specifications:

Page top