Kaspersky Industrial CyberSecurity for Networks

Editing Process Control settings for a device

March 22, 2024

ID 197882

If Process Control settings were added for a device, you can manually edit these settings when working with the devices table, the network interactions map, or the topology map. After saving the changes, Process Control settings for a device are considered to be custom settings. User-defined settings are not changed when Process Control settings are automatically detected for devices.

Only users with the Administrator role can edit Process Control settings.

To edit Process Control settings for a device:

  1. Connect to the Kaspersky Industrial CyberSecurity for Networks Server through the web interface using the Administrator account.
  2. Select the relevant asset in the Assets section on the Devices tab or in the Network map section.

    In the Network map section, you can select the relevant device on both the network interactions map and the topology map.

    The details area appears in the right part of the web interface window.

  3. Click the Edit button.

    The details area will show the following tabs for viewing and editing device information: Addresses, Settings and Custom fields.

  4. On the Addresses tab in the details area, click the button icon in the block containing the defined Process Control settings (this block is displayed if Process Control settings have been defined).

    The Edit Process Control settings window appears.

  5. Configure the Process Control settings. You can edit individual settings (for example, edit the settings for tracking system commands for a specific protocol) or reconfigure all settings in the same order as you would when adding Process Control settings.

    When you edit settings that were used in previously created tags, the application automatically deletes these tags and their associated Process Control rules. For example, if you delete a protocol, after saving the settings the application will delete all tags containing the device and deleted protocol (the Process Control rules associated with these tags will also be deleted).

  6. Click Save.

    This button is unavailable if not all required values are specified or if there are invalid values in the settings.

Information in the block containing the defined settings is updated in the lower part of the Addresses tab in the details area.